ISO 14577-6:2025 Metallic materials - Instrumented indentation test for hardness and materials parameters - Part 6: Instrumented indentation test at elevated temperature

standard byInternational Organization for Standardization , 11/01/2025

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$44.40 tax incl.

$222.00 tax incl.

(price reduced by 80 %)

This document specifies the instrumented indentation method for testing at elevated temperature for determination of hardness and other materials parameters at temperatures above ambient. Elevated temperature testing is defined in this document to be when the test piece and indenter tip are heated above the ambient conditions of the instrument to a controlled and measured temperature; insulating shielding is used to enclose the hot zone to reduce heating effects so that the majority of the instrumented indentation testing machine is at ambient conditions.

u000b

This document is restricted to test machines that have been traceably calibrated and pass an indirect verification according to ISO14577-2 when operating at elevated temperature to ensure that any effects on ambient sensors caused by the presence of a hot zone are accounted for. This document covers instrumented indentation testing at elevated temperatures in air, in inert or reducing gaseous environments, or in vacuum.

u000b

This document provides a method for instrumented indentation testing at elevated temperature with both the indenter tip and test piece actively heated, and with independent feedback control and temperature measurement of both the indenter tip and test piece.

u000b

This document provides a method for estimation of the uncertainty of the contact temperature. The uncertainty increases as the thermal conductivity of the test piece decreases. It is left to the user to decide if that uncertainty is fit for their purpose.

u000b

The test method in this document is not applicable to:

u000b

instrumented indentation testing where there is no direct measurement of the temperature of the indenter tip body itself;

u000b

instrumented indentation testing where above ambient temperatures are obtained by placing the entire instrument in a hot box to achieve iso-thermal heating of the whole system. These systems typically only achieve limited elevated temperature;

u000b

instrumented indentation testing with active heating of the test piece but only passive heating of the indenter, e.g. by proximity to the hot test piece and thermal conduction through the indentation contact, hot gas, or any combination.