AS/NZS 4776.1.1:2008
AS/NZS 4776.1.1:2008
Liquid-chilling packages using the vapour compression cycle Method of rating and testing for performance - Rating
Standards Australia
Liquid-chilling packages using the vapour compression cycle Method of rating and testing for performance - Rating
Standards Australia
<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS/NZS 4776.1.1:2008 LIQUID-CHILLING PACKAGES USING THE VAPOUR COMPRESSION CYCLE - METHOD OF RATING AND TESTING FOR...</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>1 SCOPE</text>
</bookmark>
<bookmark index='4'>
<pageno>6</pageno>
<text>2 OBJECTIVE</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>3 NORMATIVE REFERENCES</text>
</bookmark>
<bookmark index='6'>
<pageno>6</pageno>
<text>4 DEFINITIONS</text>
<bookmark index='7'>
<pageno>6</pageno>
<text>4.1 Air-cooled condenser</text>
</bookmark>
<bookmark index='8'>
<pageno>6</pageno>
<text>4.2 Bubble point</text>
</bookmark>
<bookmark index='9'>
<pageno>7</pageno>
<text>4.3 Coefficient of performance (COP)</text>
</bookmark>
<bookmark index='10'>
<pageno>7</pageno>
<text>4.4 Condenser heat rejection capacity</text>
</bookmark>
<bookmark index='11'>
<pageno>7</pageno>
<text>4.5 Cooling capacity</text>
</bookmark>
<bookmark index='12'>
<pageno>7</pageno>
<text>4.6 Dew point</text>
</bookmark>
<bookmark index='13'>
<pageno>7</pageno>
<text>4.7 Evaporator</text>
</bookmark>
<bookmark index='14'>
<pageno>7</pageno>
<text>4.8 Fouling factor</text>
</bookmark>
<bookmark index='15'>
<pageno>7</pageno>
<text>4.9 Fouling factor allowance</text>
</bookmark>
<bookmark index='16'>
<pageno>7</pageno>
<text>4.10 Liquid-chilling package</text>
</bookmark>
<bookmark index='17'>
<pageno>7</pageno>
<text>4.11 Liquid-cooled condenser</text>
</bookmark>
<bookmark index='18'>
<pageno>7</pageno>
<text>4.12 Liquid refrigerant temperature</text>
</bookmark>
<bookmark index='19'>
<pageno>7</pageno>
<text>4.13 Part-load value (PLV)</text>
</bookmark>
<bookmark index='20'>
<pageno>7</pageno>
<text>4.14 Part-load value, integrated (IPLV)</text>
</bookmark>
<bookmark index='21'>
<pageno>7</pageno>
<text>4.15 Part-load value, non-standard (NPLV)</text>
</bookmark>
<bookmark index='22'>
<pageno>8</pageno>
<text>4.16 Saturated discharge temperature</text>
</bookmark>
<bookmark index='23'>
<pageno>8</pageno>
<text>4.17 Total power input</text>
</bookmark>
<bookmark index='24'>
<pageno>8</pageno>
<text>4.18 Published ratings</text>
</bookmark>
</bookmark>
<bookmark index='25'>
<pageno>8</pageno>
<text>5 RATING REQUIREMENTS</text>
<bookmark index='26'>
<pageno>8</pageno>
<text>5.1 Test requirements</text>
</bookmark>
<bookmark index='27'>
<pageno>8</pageno>
<text>5.2 Standard rating conditions</text>
</bookmark>
<bookmark index='28'>
<pageno>8</pageno>
<text>5.3 Application rating conditions</text>
</bookmark>
<bookmark index='29'>
<pageno>8</pageno>
<text>5.4 Part-load rating</text>
</bookmark>
<bookmark index='30'>
<pageno>9</pageno>
<text>5.5 Determination of part-load performance</text>
</bookmark>
</bookmark>
<bookmark index='31'>
<pageno>10</pageno>
<text>6 PUBLISHED RATINGS</text>
<bookmark index='32'>
<pageno>10</pageno>
<text>6.1 Compliance</text>
</bookmark>
<bookmark index='33'>
<pageno>10</pageno>
<text>6.2 Fouling allowance</text>
</bookmark>
<bookmark index='34'>
<pageno>11</pageno>
<text>6.3 Standard ratings</text>
</bookmark>
<bookmark index='35'>
<pageno>11</pageno>
<text>6.4 Nameplate information</text>
</bookmark>
</bookmark>
<bookmark index='36'>
<pageno>12</pageno>
<text>7 RATING TOLERANCES</text>
<bookmark index='37'>
<pageno>12</pageno>
<text>7.1 General</text>
</bookmark>
<bookmark index='38'>
<pageno>12</pageno>
<text>7.2 Allowable tolerance</text>
</bookmark>
<bookmark index='39'>
<pageno>12</pageno>
<text>7.3 Full-load example in COP</text>
</bookmark>
<bookmark index='40'>
<pageno>12</pageno>
<text>7.4 Part-load example in COP</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>
Establishes methods of rating the performance of factory-made liquid-chilling packages using the vapour compression cycle.
This Standard sets out a procedure for rating liquid-chilling packages used in applications with temperatures as described in Clause 5.3 and as defined in Clause 4.12. This Standard covers air- and water-cooled liquid-chilling packages of cooling capacity 350 kW and above.
This Standard does not cover -
(a) liquid-chilling packages driven by other than electric motors;
(b) air-cooled liquid-chilling packages with centrifugal fans;
(c) liquid-chilling packages with remote condensers; and
(d) liquid-chilling packages for fluids other than water.
This Standard covers full-load and part-load ratings to allow for an energy analysis of the unit in different applications.
| Document Type | Standard |
| Status | Current |
| Publisher | Standards Australia |
| Committee | ME-086 |
| Supersedes |
|